6.1. Search Definition Toolbar

The search definition area sits at the top of every search tab. There you define a search or monitoring run. The drop-down list on the left shows all data profiles and temporary selections of data sources. Base your run on one of them. Use the buttons below to choose the data sources, define the search criteria, set the options and start the run.

The search definition area at the top of a search tab

Fig. 6.5 The search definition area: the profile drop-down list and data source buttons (left), the search criteria (middle), and the options and the start button (right).

Button

Description

i-choose-new-files Choose new files

Opens the Add Data Source(s) dialog, where you choose file data sources. To keep the choice for later sessions, select Save Definition to Profile.

i-choose-new-containers Choose new containers

Opens the Add Data Source(s) dialog, where you choose container (Docker or Kubernetes) data sources. To keep the choice for later sessions, select Save Definition to Profile.

i-choose-new-eventlogs Choose new Event Logs

Opens the Add Data Source(s) dialog, where you choose Windows Event Log data sources. To keep the choice for later sessions, select Save Definition to Profile.

i-compose-data-sources Compose data sources from existing profile(s)

Opens the Compose Data Source(s) dialog (see Composing Data Sources from Profiles). Available when at least one saved profile exists.

i-configure-data-sources Configure current profile

Edits the selected data sources. Unavailable when no profile or a system profile is selected.

  • If a saved profile is selected, Retrospective opens the Profile Manager (Profiles tab) and selects that profile. There you add, change or remove its data sources.

  • For a temporary selection the tooltip reads Configure current data source(s), and the Configure Data Source(s) dialog opens. There you add, change or remove data sources.

i-profile-info

Point to this bullet to see information about the selected profile or temporary selection. When the selection cannot be searched, for example because no data source is enabled, the bullet turns into a red i-profile-info-invalid marker.

i-add-datetime-criteria Add time search criterion

Opens a pop-up with the date/time search criteria to choose from (see Defining Search Criteria). Not available for monitoring: switching to Monitor removes the date/time criteria, and switching back to Search restores them.

i-event-log-filter-add Add event-log filter

Adds a filter on Windows event properties (see Event Log Search Criteria).

i-add-text-criteria Add text search criterion

Adds a text search criterion (see Defining Search Criteria).

Match all (AND) / Match any (OR)

Specifies how Retrospective combines the search criteria. The two options appear when there is more than one criterion.

  • Match all (AND) keeps log entries that match all criteria.

  • Match any (OR) keeps log entries that match any criterion.

Hide search criteria / Show search criteria

Collapses the criteria into a one-line summary, or expands them again. The link appears when there is more than one criterion, and while monitoring. Press Ctrl+O (on macOS, Cmd+O).

i-cluster-override Temporarily override the configured K8s cluster

Overrides the Kubernetes context for the next run (see Overriding the Kubernetes Context). Available when the selected profile uses exactly one configured Kubernetes context, further kubectl contexts exist, and no run or Autofind is in progress.

i-dynamic-discovery-disabled Enable dynamic discovery of files and containers created after monitoring was started

Specifies whether Retrospective reads files and containers that appear after monitoring has started. Available in Monitor mode only.

  • i-dynamic-discovery-enabled: newly appearing files and containers join the running monitoring.

  • i-dynamic-discovery-disabled: they are ignored.

i-autofind-enabled Block Autofind on dynamically detected files and containers

Specifies whether Retrospective runs Autofind on newly discovered files and containers when their entry separation (newline, date/time and so on) is not found in the first part of the log data. Available in Monitor mode with dynamic discovery on.

Note

If you adjusted the log entry separation of a data source manually, block Autofind for dynamically discovered data sources. Otherwise Autofind replaces your manual configuration.

i-field-detection-enabled Disable field detection during search/monitoring

Specifies whether Retrospective detects new name/value fields during search and monitoring. You can then assign detected fields to custom columns.

Warning

Field detection can slow down search and monitoring considerably. With large data volumes, the user interface can also respond slowly. To reduce the load:

  • Local files: decrease Max. threads for local file searching/monitoring on the System Resources preferences page.

  • Containers: decrease Max. threads for searching/monitoring in Docker and Max. threads for searching/monitoring in Kubernetes on the same page.

  • Remote files over SSH: decrease Maximum Connections in the Connection Options group on the Advanced tab of the SSH host in the Host Manager.

The tooltip of each toggle names the action a click performs. The three toggles are unavailable during a run. Their initial state comes from the Preferences dialog (see Search/Monitor and Field Detection), and each tab keeps its own setting.

The profile buttons are unavailable during a run, and so are their items in the Search/Monitor menu.

Selecting Save Definition to Profile in the Add Data Source(s) or Configure Data Source(s) dialog proposes the name Profile, or the next free Profile 01, Profile 02 and so on. The name must not be empty or already used by another profile, regardless of case. Otherwise the field is marked, its marker explains why, and OK stays unavailable.

6.1.1. Composing Data Sources from Profiles

The Compose Data Source(s) dialog lists the saved profiles with their data sources. Select the data sources you want to use. To keep the selection as a new profile, select Save Definition to Profile and enter a name. If a profile with that name exists, Duplicate Profile Name asks before it is overwritten. Without a saved profile, the selection is temporary and is named after its first data source, followed by + and the number of further data sources. OK is available when at least one data source is selected and, if you save it, the name is valid.

6.1.2. Starting a Search or Monitor

When the data sources and the search criteria are defined, start the run with the split button at the far right of the search definition area. Its main part shows the mode icon and the action. Its arrow opens the mode menu with the entries Search and Monitor. The entry for the current mode is unavailable.

  • Click i-start-search Start Search, or press Ctrl+Enter (on macOS, Cmd+Enter), to start a search. Retrospective scans the current content of the selected data sources and presents the matching log entries.

  • Choose Monitor from the mode menu, then click i-start-monitor Start Monitor to start monitoring. Retrospective keeps watching the selected data sources and appends newly arriving log entries as they appear.

While a run is in progress, the button reads Stop Search or Stop Monitor. Click it to stop the run. The profile drop-down list, the data source buttons, the search criteria and the option buttons are unavailable until the run ends.

The start button is available only when the profile and all criteria are valid and no Autofind is running; while it is unavailable, its tooltip lists these conditions. Once a result exists, changing the profile, the data sources, the criteria or a custom column shows a warning icon left of the start button. Its tooltip Search definition and result data are not in sync anymore. lists what changed.

Out-of-sync warning tooltip listing three changes

Fig. 6.6 The warning tooltip Search definition and result data are not in sync anymore.

6.1.3. Overriding the Kubernetes Context

A profile with Kubernetes data sources records the kubectl context under which it was created. Use i-cluster-override to run the same profile against another cluster. The profile itself does not change. The next search or monitoring run reads its containers through the chosen context.

The button is available when the following conditions are met: the selected profile uses exactly one configured Kubernetes context, kubectl provides more than one context, and no run or Autofind is in progress. Click the button to open a menu with all available contexts. The profile’s own context is followed by configured in parentheses. While an override is active, the chosen context is followed by overriding in parentheses, and the button shows the i-cluster-override-on icon. The configured and the active context cannot be chosen.

  • Choose a context from the menu to activate the override.

  • Choose Stop overriding K8s cluster to return to the configured context. The item appears only while an override is active.

The override applies to the current tab only. It is not saved in the profile or the session. Restarting Retrospective clears it. Selecting a profile that does not use exactly one configured Kubernetes context also clears it. Retrospective reads the contexts with kubectl config get-contexts when you select a profile or return to the tab. If kubectl cannot list them, a warning appears in the message bar at the top of the search tab. Its Kubernetes preferences link opens Data Sources ‣ Kubernetes in the Preferences dialog (see Kubernetes).

6.1.3.1. When the Recorded Cluster No Longer Exists

A recorded context stops being usable when the cluster is renamed or removed from the kubectl configuration. Suppose no override is active and kubectl config get-contexts no longer lists the recorded context. Then the run falls back to the current context. The run can then read a different cluster than the one recorded. The host column of the result table names the cluster the run actually used.

If kubectl names no current context, the run uses the recorded context unchanged and fails. It also fails when kubectl cannot be read. The profile itself never changes: its data source list in the Profile Manager keeps showing the recorded context, and the override menu still marks it configured.

Autofind, field detection and the sample load of the Configure source dialog use the same fallback to the current context. They also leave the profile unchanged.